Sewerage Code Drawings

The CTM Sewerage Code is developed to be consistent with the – SEQ Water Supply & Sewerage Design & Construction Code Amendment to WSA-02 2002 V2.3. Relevant standard drawings are listed below, with a link to CTM drawings. SEQ drawings can be accessed via https://www.seqcode.com.au/seq-sewerage-code. Note that the latest versions of SEQ drawings may not be approved by CTM, have annotations to the provisions, or may have been published after the CTM Code was published and are therefore yet to be approved (denoted with a *). The following tables provide guidance on the provisions of the SEQ drawings approved in the CTM Code.

CTM Drawings

CTM Drawing Reference MACKY
CTM–SEW–001 Typical Site and Locality Plan(PDF, 73KB) APPROVED

SEQ Sewerage Code Drawings – CTM Acceptance List

SEQ General Legend Drawing

SEQ Drawing Reference MACKY
SEQ-GEN-1100-1-B Water Supply, Sewerage, Vacuum Sewerage & Pressure Sewerage Legend APPROVED

1100 to 1102 Series - Typical Design Layout, Locality, Site Plans and Notes

SEQ Drawing Reference MACKAY
SEQ-SEW-1100-1 Design Layout Nusewers Typical Locality & Site Plan APPROVED
(REFER ADDITIONAL DRAWINGS REGARDING
PREFERENCE FOR ALIGNMENT)
SEQ-SEW-1100-2 Design Layout Rigss Typical Locality &Site plan APPROVED
(REFER ADDITIONAL DRAWINGS REGARDING
PREFERENCE FOR ALIGNMENT)
SEQ-SEW-1101-1 Design Layout Pe Nusewers Typical Longitudinal Sections APPROVED
SEQ-SEW-1101-2 Design Layout Rigss Typical Longitudinal Sections APPROVED
SEQ-SEW-1101-3 Sewerage Reticulation Typical Estate Details And Notes APPROVED
SEQ-SEW-1101-4 Sewerage Reticulation Maintenance holes notes sheet 1 of 3 NOT APPROVED*
SEQ-SEW-1101-5 Sewerage Reticulation Maintenance holes notes sheet 2 of 3 NOT APPROVED*
SEQ-SEW-1101-6 Sewerage Reticulation Maintenance holes notes sheet 3 of 3 NOT APPROVED*
SEQ-SEW-1102-1 Design Layouts Connection To
Existing Sewer Typical Schedule Of Works
APPROVED

1103 Series - Pipelaying Typical Arrangements

SEQ Drawing Reference MACKAY
SEQ-SEW-1103-1 Rigss Pipelaying Typical Arrangements APPROVED
SEQ-SEW-1103-2 Nusewer Pipelaying Typical Arrangements APPROVED
SEQ-SEW-1103-3 Sewer Road Crossings Kerb Marking Requirements NOT APPROVED*

1104 to 1106 Series - Property Arrangements

SEQ Drawing Reference MACKAY
SEQ-SEW-1104-1 Sewerage House Connection
Typical Construction Details Rigss-Sheet1
APPROVED
SEQ-SEW-1104-2 Drawing Withdrawn by SEQ
SEQ-SEW-1104-3 Sewerage House Connection
Road Crossing Property Connection Rigs
NOT APPROVED*
SEQ-SEW-1105-1 Sewerage House Connection Typical Construction Details Rigss-Sheet2 APPROVED
SEQ-SEW-1106-1 PE Nusewers Property
Connections Typical Layout
NOT APPROVED
SEQ-SEW-1106-2 PE Nusewers Typical Property
Connection Type A1, A2 Standard & Extended
APPROVED
(NOTE THAT SEDIMENT TRAPS ARE NOT TO BE
INCLUDED – AS PER UW COMMENTS)
SEQ-SEW-1106-3 PE Nusewers Typical Property
Connection Type A3, A4 Standard & Extended
APPROVED
(NOTE THAT SEDIMENT TRAPS ARE NOT TO BE
INCLUDED – AS PER UW COMMENTS)
SEQ-SEW-1106-4 PE Nusewers Typical Property
Connection Type B1 to B4 Sloped Connections
APPROVED
(NOTE THAT SEDIMENT TRAPS ARE NOT TO BE
INCLUDED – AS PER UW COMMENTS)
SEQ-SEW-1106-5 PE Nusewers Typical Property Connection Type C1 to C4 Vertical Riser APPROVED
(INTERNAL DROPS ONLY – NO EXTERNAL
DROPS ALLOWED)
SEQ-SEW-1106-6 PE Nusewers Typical Twin
Property Connection Type C1 to C4 Vertical
Riser
NOT APPROVED
SEQ-SEW-1106-7 PE Nusewers Typical Twin &
Single Property Connections
Drawing Withdrawn by SEQ
SEQ-SEW-1106-8 PE Nusewers Road Crossing Property Connections. NOT APPROVED*

1200 to 1207 Series - Trenching and Backfill

SEQ Drawing Reference MACKAY
SEQ-SEW-1200-1 Soil Classification Guidelines And Allowable Bearing Pressures For Anchors And Thrust Blocks APPROVED
SEQ-SEW-1200-2 Embedment & Trench fill Typical Arrangement APPROVED
SEQ-SEW-1201-1 Typical Standard Embedment
Flexible & Rigid Pipes
APPROVED
SEQ-SEW-1202-1 Typical Special Embedment Inadequate Foundations Requiring Over
Excavation & Replacement
APPROVED
SEQ-SEW-1203-1 Typical Special Embedment Concrete And Stabilised Supports APPROVED
SEQ-SEW-1204-1 Typical Special Embedment Support Utilising Piles APPROVED
SEQ-SEW-1205-1 Typical Trench And Bedding Details Within Existing Roads Type 14 To 17 APPROVED
SEQ-SEW-1206-1 Typical Bulkheads & Trench Stops APPROVED
SEQ-SEW-1207-1 Trench Drainage Typical Systems APPROVED
SEQ-SEW-1207-2 Typical Drainage Of Sewer Trenches And Diversion Drains APPROVED (NOTE: DIVERSION TO STORMWATER DRAIN DETAIL NOT MANDATORY)

1300 to 1307 Series - Maintenance Holes, Maintenance Shafts and Sulphide Control

SEQ Drawing Reference MACKAY
SEQ-SEW-1300-1 Maintenance Holes < Dn300 Sewer Types P1, P2 & P3 Typical Pre-Cast APPROVED
(NOTE: CTM PREFERENCES ARE FOR CAST INSITU MANHOLES)
SEQ-SEW-1301-1 Cast in-Situ Maintenance Hole Typical Coping & Anchor Bracket Details APPROVED
(NOTE: CTM PREFERENCES ARE FOR CAST INSITU MANHOLES)
SEQ-SEW-1301-2 "G"Type-Pe NuSewers Typical Maintenance Hole Details APPROVED
(NOTE: CTM PREFERENCES ARE FOR CAST INSITU MANHOLES)
SEQ-SEW-1301-3 "G"Type- Pe NuSewers Typical Maintenance Hole And Slab Details ACCEPTED
(NOTE THAT STEP IRONS ARE NOT REQUIRED FOR MANHOLES)
SEQ-SEW-1301-4 "G"Type- Pe NuSewers Typical Maintenance Hole Structural G.A. Details Type 'A' NOT APPROVED*
SEQ-SEW-1301-5 'G' Type - PE NuSewers Typical Maintenance Hole Structural G.A. Deatails Type 'C' & Type 'D' NOT APPROVED*
SEQ-SEW-1301-6 Drawing Withdrawn by SEQ
SEQ-SEW-1301-7 Drawing Withdrawn by SEQ
SEQ-SEW-1301-8 'F' Type - PE Nusewers Typical Maintenance Hole G.A Details APPROVED
(INTERNAL DROPS ONLY-NO EXTERNAL DROPS ALLOWED)
SEQ-SEW-1301-9 'F' Type - PE Nusewers Typical Maintenance Hole and Slab G.A Details APPROVED
(NOTE THAT STEP IRONS ARE NOT REQUIRED FOR MANHOLES)
SEQ-SEW-1301-10 'F' Type - PE Nusewers Typical Maintenance Hole Structural G.A. Details Type 'A' NOT APPROVED*
SEQ-SEW-1301-11 'F' Type - PE Nusewers Typical Maintenance Hole Details Structural G.A. Details Type 'C' & Type 'D' NOT APPROVED*
SEQ-SEW-1301-12 Drawing Withdrawn by SEQ
SEQ-SEW-1301-13 Drawing Withdrawn by SEQ
SEQ-SEW-1301-14 "X"Type Deep Maintenance Hole Typical arrangement and G.A. Details Sewers 1200 NB or Less NOT APPROVED
SEQ-SEW-1301-15 "X"Type Deep Maintenance Hole Typical Arrangement and G.A Details Sewer > 1200 NB NOT APPROVED
SEQ-SEW-1301-16 "X"Type Deep Maintenance Hole Typical Arrangement and G.A Details Sewer 600 NB or Less with drop pipe. NOT APPROVED
SEQ-SEW-1301-17 "X"Type Deep Maintenance Hole Typical Arrangement and G.A Details Sewer 675 NB to 900 NB with drop pipe and safety chain detail. NOT APPROVED
SEQ-SEW-1301-18 "X"Type Deep Maintenance Hole Typical junction details. NOT APPROVED
SEQ-SEW-1301-19 "X"Type Deep Maintenance Hole Typical top slab G.A details NOT APPROVED
SEQ-SEW-1301-20 "X"Type Deep Maintenance Hole Structural G.A. Details Sewers 600 NB or less NOT APPROVED*
SEQ-SEW-1301-21 "X"Type Maintenance Hole Structural Reinforcement Details Sewers 600 NB or less NOT APPROVED*
SEQ-SEW-1301-22 "X"Type Deep Maintenance Hole Structural G.A. Details Sewers > 600 NB to 1200 NB NOT APPROVED*
SEQ-SEW-1301-23 "X"Type Deep Maintenance Hole Structural reinforcement details Sewers > 600 NB to 1200 NB NOT APPROVED*
SEQ-SEW-1301-24 "X"Type Deep Maintenance Hole Structural G.A. Details Sewers > 1200 NB NOT APPROVED*
SEQ-SEW-1301-25 "X"Type Deep Maintenance Hole Structural Reinforcement Details Sewers > 1200 NB NOT APPROVED*
SEQ-SEW-1301-26 'G', 'F', 'X' Type Maintenance Holes Top Slabs Reinforcement details NOT APPROVED*
SEQ-SEW-1301-27 Typical M.S. and S.S. Ladder and Associated Fittings NOT APPROVED
SEQ-SEW-1302-1 Maintenance Holes Cast In-Situ and Precast typical Pipe Connection details APPROVED
SEQ-SEW-1303-1 Maintenance Holes Sewers ≤ DN300 Typical Changes In Level Details APPROVED
(INTERNAL DROPS ONLY –
NO EXTERNAL DROPS ALLOWED)
SEQ-SEW-1303-2 Iron Inspection Bends For Typical Internal Drop Pipes In Sewerage
Manholes
NOT APPROVED
SEQ-SEW-1303-4 Typical Stainless Steel Brackets
For Dn100 And Dn150 Upvc Drop Pipes
NOT APPROVED
SEQ-SEW-1304-1 Maintenance Holes Sewers ≤ DN300 Typical Channel Arrangements APPROVED
(INTERNAL DROPS ONLY – NO EXTERNAL DROPS ALLOWED)
SEQ-SEW-1305-1 Maintenance Holes Typical Channel Details APPROVED
SEQ-SEW-1306-1 Maintenance Holes Typical Alternative Drop Connections APPROVED
(INTERNAL DROPS ONLY – NO EXTERNAL DROPS ALLOWED)
SEQ-SEW-1307-1 DN1000 to DN1500 Cast In-Situ Maintenance Holes Typical Details APPROVED
SEQ-SEW-1307-2 Sulphide Control Sewer Maintenance Hole - Re lined General Arrangement NOT APPROVED
SEQ-SEW-1307-3 Sulphide Control Sewer Maintenance Hole-PE Lined Details and vent pole details NOT APPROVED
SEQ-SEW-1307-4 Sulphide Control Cut-In to existing sewer maintenance hole details NOT APPROVED
SEQ-SEW-1307-5 Sulphide Control Sewer Maintenance Hole - PE Lined structural G.A Details NOT APPROVED*
SEQ-SEW-1307-6 Sulphide Control Sewer Maintenance Hole - PE Lined structural Reinforcement Details NOT APPROVED*
SEQ-SEW-1307-7 Sulphide Control Sewer Maintenance Hole Top Slab Reinforcement Details NOT APPROVED*

1308 Series - Maintenance Hole Covers

SEQ Drawing Reference MACKAY
SEQ-SEW-1308-1 Typical Maintenance Hole and Shaft Cover and Surround Detail APPROVED
SEQ-SEW-1308-2 Maintenance Hole Cover Sewer-Class B-Concrete In Fill Typical Frame Details NOT APPROVED
SEQ-SEW-1308-3 Maintenance Hole Cover Sewer-Class B-Concrete In Fill Typical Cover Details NOT APPROVED
SEQ-SEW-1308-4 Maintenance Hole Cover Sewer-Class B-Concrete In Fill Typical Lifting Hole Details NOT APPROVED
SEQ-SEW-1308-5 Maintenance Hole Cover Sewer-Class B-Bolt Down Typical Frame Details APPROVED
SEQ-SEW-1308-6 Maintenance Hole Cover Sewer-Class B-Bolt Down Typical Cover Details APPROVED
SEQ-SEW-1308-7 Maintenance Hole Cover Sewer-Class B-Bolt Down Typical Cover Details APPROVED
SEQ-SEW-1308-8 Maintenance Hole Cover Sewer-Class D-Bolt Down Typical Base Frame Details APPROVED
SEQ-SEW-1308-9 Maintenance Hole Cover Sewer-Class D-Bolt Down Typical Riser Ring Details APPROVED
SEQ-SEW-1308-10 Maintenance Hole Cover Sewer - Class D -Bolt Down Typical Cover Details APPROVED
SEQ-SEW-1308-11 Maintenance Hole Cover Sewer-Class D-Bolt Down Typical Cover Details APPROVED

1309 to 1312 Series - Special Manholes

SEQ Drawing Reference MACKAY
SEQ-SEW-1309-1 "Y" Type Maintenance Hole Sewers DN600 & DN750 Typical Arrangement APPROVED
SEQ-SEW-1309-2 "Y" Type Maintenance Hole DN1500 and DN1800 Structural G.A. Details NOT APPROVED*
SEQ-SEW-1309-3 "Y" Type Typical Maintenance Hole DN1500 and DN1800 Structural Reinforcement Details NOT APPROVED*
SEQ-SEW-1309-4 "Y" Type Typical Maintenance Hole DN1500 and DN1800 top slab Reinforcement Details NOT APPROVED*
SEQ-SEW-1310-1 "Z1" Type Non-Trafficable Typical Grip MH Option Dn1200 And Larger Sewers APPROVED
SEQ-SEW-1311-1 "Z2" Type Typical Tunnel Jacking Shaft-Caisson Option APPROVED
SEQ-SEW-1312-1 "Z3" Type Typical Tunnel Receival Shaft Manhole Option APPROVED

1313 to 1316 Series - Maintenance Shafts Sewer Connections and Bends

SEQ Drawing Reference MACKAY
SEQ-SEW-1313 -1 Maintenance Hole Sewer Connection Details All Pipe Materials APPROVED
SEQ-SEW-1314-1 MC, MS AND TMS TYPES FOR DN225 and Smaller RIGSS Typical arrangement details APPROVED
SEQ-SEW-1314-2 MC, MS, TMS AND Variable Bend FOR RIGSS Typical Arrangement Details NOT APPROVED
SEQ-SEW-1314-3 Gravity Sewers Rigss Typical In-Line Bend Details NOT APPROVED
SEQ-SEW-1315-1 Pe NuSewers Typical Maintenance Shaft And Terminal Entry Point NOT APPROVED
SEQ-SEW-1316-1 Pe NuSewers Typical Maintenance Structure Cover Frame And Support Details APPROVED

1400 to 1403 Series - Buried Crossings

SEQ Drawing Reference MACKAY
SEQ-SEW-1400-1 Buried Crossings Typical
Siphon Arrangement
APPROVED
SEQ-SEW-1401-1 Typical Buried Crossings
Railways
NOT APPROVED
SEQ-SEW-1402-1 Typical Buried Crossings Major
Roadways
APPROVED
SEQ-SEW-1403-1 Typical Buried Crossings Bored
And Jacked Encasing Pipe Details
APPROVED

1404 to 1406 Series - Aerial Crossings

SEQ Drawing Reference MACKAY
SEQ-SEW-1404-1 Typical Aerial Crossings Aqueduct APPROVED
SEQ-SEW-1405-1 Typical Aerial Crossings Aqueduct Protection Grille APPROVED
SEQ-SEW-1406-1 Aerial Crossings Typical Bridge Crossing Concepts APPROVED

1407 to 1408 Series - Ventilation and Water Seal Arrangements

SEQ Drawing Reference MACKAY
SEQ-SEW-1407-1 Typical Ventilation Systems Induct Vent APPROVED
SEQ-SEW-1408-1 Water seal Arrangements Typical Mains Type NOT APPROVED
SEQ-SEW-1408-2 Water seal Arrangements Typical Maintenance Hole System NOT APPROVED

1409 to 1413 Series - Overflow Details

SEQ Drawing Reference MACKAY
SEQ-SEW-1409-1 Standard Overflow Flap Valve Chamber-Type1 Typical Chamber Details NOT APPROVED
SEQ-SEW-1409-2 Standard Overflow Flap Valve Chamber-Type1 Typical Top Slab And Flap Details NOT APPROVED
SEQ-SEW-1410-1 Standard Overflow Flap Valve Chamber-Type2 Typical Chamber Details NOT APPROVED
SEQ-SEW-1410-2 Standard Overflow Flap Valve Chamber-Type 2 Typical Top Slab And Flap Details NOT APPROVED
SEQ-SEW-1411-1 Standard Overflow Flap Valve Chamber-Type3 Typical Chamber Details NOT APPROVED
SEQ-SEW-1411-2 Standard Overflow Flap Valve Chamber-Type3 Typical Top Slab And Flap Details NOT APPROVED
SEQ-SEW-1411-3 Standard Overflow Flap Valve Chamber-Types 1,2, & 3 Structural G.A. Details NOT APPROVED*
SEQ-SEW-1411-4 Standard Overflow Flap Valve Chamber-Types 1,2, & 3 Typical Reinforcement Details NOT APPROVED*
SEQ-SEW-1411-5 Overflow Flap valve Top Slab Reinforcement Details NOT APPROVED*
SEQ-SEW-1412-1 Typical Overflow Details From Pump Well Or Manhole Shielded Outlet NOT APPROVED
SEQ-SEW-1412-2 Typical Overflow Shield Shielded Outlet APPROVED
SEQ-SEW-1413-1 Sewerage Overflow Arrangement Typical Overflow with Screened Outlet APPROVED
SEQ-SEW-1413-2 Sewerage Overflow Arrangement Typical Overflow 'comb seperator' Screened Outlet NOT APPROVED*

1500 Series - Insertions and Repair Systems

SEQ Drawing Reference MACKAY
SEQ-SEW-1500-1 Insertions And Repair Systems Typical Pipe cut-In methods APPROVED
SEQ-SEW-1501-1 Insertions And Repair Systems Typical Insertion Of Junctions APPROVED
SEQ-SEW-1502-1 Insertions And Repair Systems Typical Maintenance Structures APPROVED

Additional Drawings

A3-03977 B - Building over sewers - acceptable site plan(PDF, 97KB)

Superseded Drawings

A3-00856 B - Sewer Manholes(PDF, 220KB)

A3-04196 C - Design layouts typical locality and site plan(PDF, 208KB)

A3-04197 C - Design layouts longitudinal sections(PDF, 165KB)

A3-04198 B - Design layouts connection to existing sewer, schedule of works(PDF, 205KB)

A3-04199 D - Pipe laying typical arrangements(PDF, 135KB)

A3-04203 D - Property connection details, buried interface method(PDF, 211KB)

A3-04208 D - Standard embedment, flexible and rigid pipes(PDF, 212KB)

A3-04209 D - Special embedment, inadequate foundations requiring over excavation and replacement(PDF, 222KB)

A3-04210 D - Special embedment supporting utilising piles(PDF, 187KB)

A3-04211 D - Special embedment, concrete and stabilising supports(PDF, 184KB)

A3-04212 D - Trench drainage, bulkheads and trenchstop(PDF, 196KB)

A3-04213 D - Trench drainage typical systems(PDF, 205KB)

A3-04214 D - Vertical and near verticals exposed and concealed methods(PDF, 188KB)

A3-04215 E - Maintenance holes sewers ≤ DN300 Precast types P1 and P2(PDF, 221KB)

A3-04216 D - Maintenance holes sewers ≤ DN300 cast in-situ types C1 and C2(PDF, 161KB)

A3-04217 D - Maintenance holes pipe connection details(PDF, 188KB)

A3-04218 C - Maintenance holes sewers ≤ DN 300 changes in level details(PDF, 186KB)

A3-04219 C - Maintenance holes sewer ≤ DN 300 typical channel arrangements(PDF, 166KB)

A3-04220 C - Maintenance holes, typical channel details(PDF, 149KB)

A3-04221 E - Maintenance holes, alternative drop connection(PDF, 171KB)

A3-04223 D - Maintenance holes, typical manhole cover arrangements(PDF, 207KB)

A3-04224 D - Maintenance holes, sewers DN 375 to DN 750(PDF, 204KB)

A3-04226 C - Aerial crossing aqueduct protection grille(PDF, 138KB)

A3-04227 C - Aerial Crossing Bridge Crossing Concepts(PDF, 171KB)

A3-04228 D - Flanged joints, bolting details(PDF, 230KB)

A3-04229 E - Maintenance holes, typical installation(PDF, 164KB)

A3-04230 E - Maintenance Shafts, MS & Variable Bend Installations(PDF, 142KB)

A3-04231 E - Maintenance shafts, TMS and connection installations(PDF, 185KB)

A3-04232 E - Maintenance shafts, typical MS cover arrangements(PDF, 175KB)

A3-04234 C - Buried crossings railways sewerage pipes(PDF, 206KB)

A3-04235 C - Buried crossings, major roadways(PDF, 212KB)

A3-04236 C - Buried crossings, bored and jacked encasing pipe details sewerage pipes(PDF, 174KB)

A3-04237 C - Aerial crossings, aqueduct sewerage pipes(PDF, 236KB)

A3-04243 D - Water seal arrangements, maintenance hole system(PDF, 154KB)

A3-04246 C - Insertions and repair systems, cut-in method(PDF, 200KB)

A3-04247 C - Insertions and repair systems, insertions of junctions(PDF, 192KB)

A3-04248 D - Insertions and repair systems, maintenance structures(PDF, 215KB)